Turbine Gas Meter TBX100/L

Liên hệ

Specifications of actual flow display model (TBX series)

Model typeTBX30TBX100TBX100FTBX150F
Operating flow rate range *14~30m3/h10~100m3/h10~100m3/h12.5~150m3/h
Maximum operating pressure100kPa
AccuracyFlow rate measuring parts±1%FS
DisplayTrip flow rate *2Large LCD in 6 digits with minimum reading of 10 LLCD in 6 digits with minimum reading of 100 L
Unadjusted gross accumulated flow rate *3Large LCD in 8 digits with minimum reading of 10 LLCD in 8 digits with minimum reading of 100 L
Unadjusted instantaneous flow rateLCD in 3 digits with minimum reading of 0.1m3/hLCD in 4 digits with minimum reading of 0.1m3/hLCD in 3 digits with minimum reading of 1m3/h
Diameters of connected partsRc1 1/2、Rc1 1/4Rc2JIS 10K 50A flange
Operating temperature range-10℃~+60℃
Measurable gases *4Town gas, LPG, nitrogen, etc.
Mounting positionHorizontal and vertical
Installation locationIndoor
Power sourceBuilt-in lithium battery or external power supply (24 VDC)
Output signalTwo systems of open-drain output (unit pulse and high-density pulse * 5)
Standard pulse unit width * 6TBX30 and TBX100: 10 L/P; TBX150: 100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec
MaterialsAluminum alloyCast ironAluminum alloy
Mass0.8kg1.8kg7.0kg2.5kg
Nhà cung cấp

Chưa cập nhật

Xuất xứ

Chưa cập nhật

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “Turbine Gas Meter TBX100/L”