Chi tiết sản phẩm Bộ đo và điều chỉnh lưu lượng khí ga – 4800 Brooks Việt Nam
Bộ đo và điều chỉnh lưu lượng khí ga – 4800 Brooks Việt Nam
Bộ đo và điều chỉnh lưu lượng khí ga
4850 Brook Việt nam
4860 Brooks instrument Việt Nam
4800 Series Elastomer Sealed Thermal Mass Flow Controllers & Meters Việt Nam
Features
- Flow response time (settling time) <0.75 seconds
- Innovative MEMS sensor and proprietary PID algorithm
- Compact size is less than half the size of typical thermal MFCs: 1” x 3” x 4” (25 mm x 76 mm x 101 mm)
- Optional Local Operator Interface (LOI) simplifies set-up and operation; free LabVIEW VI download for monitoring and zeroing the device
- Digital capability via RS-232
Benefits
- Well suited for wide range of common, non-corrosive gases
- Fast response time ensures rapid steps during process recipe changes
- Excellent for OEMs: Compact size eases integration into tight machine spaces and speeds installation
- Optional Local Operator Interface (LOI) is a turnkey solution for local indication, set point control and device configuration; eliminates need for remote secondary electronics
- Variety of communication options makes it easy to align with user requirements
Applications
- Heat treating, cutting/welding and other thermal processes
- Solar/thin film physical vapor deposition (PVD) systems
- Analytical devices to measure and control reagent, calibration and sample gas flow
4850 | 4860 | |
Product Type | Mass Flow Controller | Mass Flow Meter |
Flow Range (Full Scale Capacity) | 50 sccm – 40 slpm | 50 sccm – 40 slpm |
Accuracy | 3.0% F.S. 1.0% F.S. (optional) | 3.0% F.S. 1.0% F.S. (optional) |
Repeatability | 0.15% F.S. | 0.15% F.S. |
Response Time | Normally Closed Valve: 300 ms – <1 sec | Normally Closed Valve: 300 ms – <1 sec |
Max Pressure | 150 psig/10 barg | 150 psig/10 barg |
Diagnostic Capability | Status Lights: MFC Health, Network Status Alarms: Sensor Output, Control Valve Output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port: RS485 via 2.5 mm jack | Status Lights: MFC Health, Network Status Alarms: Sensor Output, Control Valve Output, Over Temperature, Power Surge/Sag, Network Interruption Diagnostic/Service Port: RS485 via 2.5 mm jack |
Analog Communication | 0-5 Vdc 4-20 mA | 0-5 Vdc 4-20 mA |
Digital Communication | RS232 | RS232 |
Xem thêm các sản phẩm khác của Hãng Brooks tại đây